TRANSFORMERS AND AUTOTRANSFORMERS, VOLTAGE 10 UP TO 220 KV FOR ELECTRIFIED RAILWAYS WITH ALTERNATIVE CURRENT

Transformers and autotransformers, voltage 10 up to 220 kv for electrified railways with alternative current
Oil-immersed three-phase two-winding converter transformers, voltage class 10 kV

Transformers with off-circuit tap changer of power winding, the range of tap-changing on the power winding ± 2 x 2,5 %, with the cooling system ONAF. These transformers are designed to supply the power to the areas of semiconductor converters of direct current on the traction substations of electrified railways.
Type, regulatory document Rated voltage (no-load), kV Connection of windings Losses, kW Total Weight, kg
Power winding Valve side winding no load losses short-circuit losses
3-phase, ONAF, OCTC, split-winding, converter 12,5 MVA (ТУ 16 ИБМД.672434.050-2001) 10,0 1,305 Y/DY-11-0 16,0 71,5 22500

Oil-immersed one-phase traction-feeding transformers, voltage class 10 and 25 kV
Transformers with the cooling system ODAF are designed for transformation of the voltage of contact network into the voltage of traction motor circuits, feeding, auxiliaries and heating, as well as for the transformation of voltage of the traction engines into the voltage of the contact network, feeding and auxiliaries of the line electric locomotive, heating and power supply of the train.
Type, regulatory document Rated Voltage of the power winding, kV Connection of windings Losses, kW Total Weight, kg
no load losses short-circuit losses
1-phase, ODAF, for electric locomotives 8 MVA (ТУ 16 ИБМД.672424.005-2002) 10 1/1/1/1/1/1-0-0-0-0-0 4,5 103,5 9734
1-phase, ODAF, for electric locomotives 4,35 MVA (ТУ 16 ВЕИЮ.672324.001-2005) 25 1/1/1/1/1-0-0-0-0 3,7 56,8 7800
1-phase, ODAF, for electric locomotives 5,7 MVA (ТУ 16 ВГЕИ.672424.001-2007) 25 1/1/1/1/1/1-0-0-0-0-0 5,5 51,5 (heating winding power is 300 кVА) 9300

Oil-immersed one-phase two-winding power transformers and autotransformers, voltage class up to 35 kV
Transformers with the splitted LV winding, with off-circuit tap changer, the range of tap-changing on HV side ± 2 x 2,5 %, with the cooling system ONAN. These transformers are designed for installation, regulated shunt capacitive compensation of reactive power, installed on the section points of electrified railways and as the boosting transformer to raise up the voltage of the retarding phase of traction substation.
Type, regulatory document Type, regulatory document Connection of windings Losses, kW Total Weight, kg
HV LV no load loss short-circuit loss
1-phase, OCTC, ONAN, split winding, for railways 10 MVA (ТУ 16 ИБМД.672413.005-2002) 27,5 1,25; 2,5-2,5; 3,75; 5,00 1/1-1-0-0 10,0 50,0 23100
Autotransformers without tap-changing, with the cooling system ONAN. These transformers are designed for the feeding of contact net-works of electrified railways.
Type, regulatory document Type, regulatory document Connection of windings Losses, kW Total Weight, kg
HV LV no load loss short-circuit loss
Auto, 1-phase, ONAN, for railways 10 MVA (GOST R 51559-2000) 27,5x2 27,5 1 auto 6,5 26,0 14265
Auto, 1-phase, ONAN, for railways 16 MVA (GOST R 51559-2000) 27,5x2 27,5 1 auto 9,0 33,5 19000
Transformer with the splitted LV winding, with on-load tap changer on LV side, the range of tap-changing ±8x2%, with the cooling system ONAF. These transformers are designed for the power supply of the railways, electrified with alternative current.
Type, regulatory document; Rated voltage, kV Connection of windings Losses, kW Total Weight, kg
HV MV LV no load loss short-circuit loss
1-phase, 3-winding, OLTC, ONAF, split winding, for railways 25 MVA (GOST R 51559-2000) 115 38,5 27,5-27,5 1/1/1-1-0-0 26,0 135 64200
1-phase, 3-winding, OLTC, ONAF, split winding, for railways 25 MVA (GOST R 51559-2000) 115 11,0 27,5-27,5 1/1/1-1-0-0 26,0 135 64200
1-phase, 3-winding, OLTC, ONAF, split winding, for railways 25 MVA (GOST R 51559-2000) 230 11,0 27,5-27,5 1/1/1-1-0-0 29,0 130 83500
1-phase, 3-winding, OLTC, ONAF, split winding, for railways 25 MVA (GOST R 51559-2000) 230 38,5 27,5-27,5 1/1/1-1-0-0 29,0 130 83500
Oil-immersed three-phase three-winding power transformers, voltage class 110 kV
Transformers with on-load tap changer on the HV side, the range of tap-changing ± 16%, ± 9 steps and with off-circuit tap changer on the MV side, the range of tap-changing ±(2x2,5%), with the cooling system ONAF. These transformers are designed for the power supply of the railways, electrified with alternative current.
Type, regulatory document; Rated voltage, kV Connection of windings Losses, kW Total Weight, kg
HV MV LV no load loss short-circuit loss
3-phase, 3-winding, OLTC, ONAF, for railways 16 MVA (GOST R 51559-2000) 115 27,5 6,6; 11,0 Yн/D/D-11-11 19,0 100 45500
3-phase, 3-winding, OLTC, ONAF, for railways 25 MVA (GOST R 51559-2000) 115 27,5 11,0; 6,6 Yн/Yн/D-0-11 28,5 140 61400
3-phase, 3-winding, OLTC, ONAF, for railways 40 MVA (GOST R 51559-2000) 115 38,5 27,5 Yн/Yн/D-0-11 39,0 200 81000
3-phase, 3-winding, OLTC, ONAF, for railways 40 MVA (GOST R 51559-2000) 115 38,5 27,5 Yн/Yн/D-0-11 36,0 220 81000

Oil-immersed three-phase three-winding power transformers, voltage class 220 kV
Transformer with on-load tap changer on HV side, the range of tap-changing ± 12%, ± 12 stages and with off-circuit tap changer on MV side, the range of tap-changing ±(2x2,5%), with the cooling system ONAF. These transformers are designed for power supply of the electrified railways on alternative current.
Type, regulatory document; Rated voltage, kV Connection of windings Losses, kW Total Weight, kg
HV MV LV no load loss short-circuit loss
3-phase, 3-winding, OLTC, ONAF, for railways 25 MVA (GOST R 51559-2000) 230 27,5 6,6; 11,0 Yн/D/D-11-11 40,0 130 ***
3-phase, 3-winding, OLTC, ONAF, for railways 25 MVA (GOST R 51559-2000) 230 38,5 27,5 Yн/D/D-11-11 40,0 130 ***
3-phase, 3-winding, OLTC, ONAF, for railways 40 MVA (GOST R 51559-2000) 230 27,5 6,6; 11,0 Yн/D/D-11-11 54,0 54,0 ***
3-phase, 3-winding, OLTC, ONAF, for railways 40 MVA (GOST R 51559-2000) 230 38,5 27,5 Yн/D/D-11-11 54,0 54,0 ***

Mobile Oil-immersed three-phase two-winding power transformers, voltage classes 110kV and 220 kV
Transformers with on-load tap changer on HV side off-circuit, the range of tap-changing ± 2 x 2,5%, with the cooling system OFAF. These transformers are designed for operation on mobile traction substation of railways power network
Type, regulatory document Rated voltage, kV Connection of windings Losses, kW Total Weight, kg
HV LV no load loss short-circuit loss
3-phase, OFAF, OCTC, converter 32 MVA (ТУ 16 ИБМД.672534.005-2003) 110 27,5; 11,0 YH/D-11 27,0 141 59000
3-phase, OFAF, OCTC, converter 32 MVA (ТУ 16 ИБМД.672534.005-2003) 220; 154 27,5 YH/D-11 30,0 120 72000

*** According to the design documents on the results of acceptance tests.